top of page
  • Writer's pictureJeff Culkin

Worcester Greenstar Cdi SE or D5 fault Code


This is not a fault code. Hense why you cannot find it in the service and installation book. This is a special feature of some Worcester CDi boilers .It is actually a reminder that the boiler requires a service based on burner hours.

To reset the code follow this steps;

  • Press and hold Spanner button until it becomes orange

  • Press and hold Eco button until 5A displays

  • CS press and release Eco button

  • press and release CS

  • Hold Until brackets appear then release

  • then press spanner button

Check if the burner requires cleaning by following the test producer using a mano-meter on the internal test point as outlined in the service and installations manual.

Comments

You do not have permission to add comments.


12,590 views0 comments

Recent Posts

See All
bottom of page