top of page

Worcester Greenstar Cdi SE or D5 fault Code

​

This is not a fault code. Hense why you cannot find it in the service and installation book. This is a special feature of some Worcester CDi boilers .It is actually a reminder that the boiler requires a service based on burner hours.

 

To reset the code follow this steps;

  • Press and hold Spanner button until it becomes orange 

  • Press and hold Eco button until 5A displays

  • CS press and release Eco button 

  • press and release CS 

  • Hold Until brackets appear then release 

  • then press spanner button 

Check if the burner requires cleaning by following the test producer using a mano-meter on the internal test point as outlined in the service and installations manual.

CULKIN PLUMBING AND HEATING LTD   

​

Director JEFF CULKIN MCIPHE RP RHP EngTEch

​

Gas Safe Reg no 305929    Company No. 07980305    VAT No. GB172932986    D-U-N-S Number: 21-827-8135

North

​

* Commercial Gas Heating and Boilers * Legionella Inspections and Water Treatment. * PAT Testing. * Boiler Repairs and Servicing.* Boiler Installation, G3 Cylinder Installation * Heating System Servicing.* Mechanical Surveys.* Leak detection and damp tracing.