Identifiable fault codes recurring and intermittent issues‎ - Keston C40 C55 Fault error codes E03 E


LOCKOUT

If the fault is persistent or more severe the boiler will lockout with a error code.

When the boiler

has entered this error mode it will not attempt to restart until the "Reset" button is pressed.

ERROR CODES

Display

Description of fault

Code Description Our comments

E00

Flame detected when not expected. Check boiler earth and probe condition.

E02

No ignition after restart. Check gas supply, gas valve operation and ignitor

electrode spark generation

E03

Gas valve faulty or not connected

E04

Power has been reset whilst boiler was in lockout

E11

Internal electronics error - rest or replace control box

E12

Thermal fuse blown or flue overheat thermostat activated.

E18

Flow overheat - check water circulation

E19

Maximum return temperature exceeded. Check circulation.

E25

Flow temperature increased too quickly. Check water circulation.

E28

Fan not rotating - check fan connection and fan for fault.

E30

Difference between flow and return temperatures too high. Check circulation. Possible pump failure

E31

Flow thermistor short circuit - check/replace connections/thermistor check for leaks, water causing short circuit

E32

Return thermistor short circuit - check/replace connections/thermistor

check for leaks, water causing short circuit

E36

Flow thermistor open circuit - check/replace connections/thermistor

check for leaks, water causing short circuit

E37

Return thermistor open circuit - check/replace connections/thermistor

check for leaks, water causing short circuit

E44

Low water pressure

Check for leaks check PRV, expansion vessel

BOCK CODES

Code Description Our comments

B18 Flow temperature exceed 95

B19 Return temperature exceeded 95

B24 Return temperature exceeded flow temperature. Check pump direction on boiler

B25 Flow temperature climbing too quickly. Possible air lock or circulation blockage

B26 Low water pressure Check for leaks check PRV, expansion vessel

B28 No signal from fan. Possible fan disconnected or faulty

B29 Incorrect signal from fan. Possible fan faulty

B30 Difference between flow and return temperatures too high. Check water circulation Possible pump failure

B65 Waiting for fan to start


Recent Posts

See All

Gas Pipe Sizing

All the facts and questions around gas pipe sizing explained; New boiler, Property renovation, or adding appliances etc. Common problems and common misinformation. To understand the need for correct g

CULKIN PLUMBING AND HEATING LTD   

Director JEFF CULKIN ACIPHE RP RHP    29B CHANDOS ROAD    WILLESDEN GREEN    LONDON    NW2 4LS  , England, UK

Gas Safe Reg no 305929    Company No. 07980305    VAT No. GB172932986    D-U-N-S Number: 21-827-8135

Primary Coverage;   

NW2 Willesden Green, Cricklewood, and Childs Hill   

NW3 Hampstead, Belsize   

NW5 Kentish Town, Camden   

NW6 West Hampstead, Kilburn, and Queens Park   

NW8 St Johns Wood   

NW10 Kensal Rise, Harlesden, Willesden   

NW11 Golders Green Hampstead Garden Suburb   

W9 Maida Vale   

W10 North Kensington, Queens Park   

W11

* Commercial Gas Heating and Boilers * Legionella Inspections and Water Treatment. * PAT Testing. * Boiler Repairs and Servicing.* Boiler Installation, G3 Cylinder Installation * Heating System Servicing.* Mechanical Surveys.* Leak detection and damp tracing.